Skip to page content
USDA Forest Service
  
Treesearch

Research & Development Treesearch

 
Treesearch Home
About Treesearch
Contact Us
Research & Development
Forest Products Lab
International Institute of Tropical Forestry
Northern
Pacific Northwest
Pacific Southwest
Rocky Mountain
Southern
Help
 

GeoTreesearch


Science.gov - We Participate


USA.gov  Government Made Easy


Global Forest Information Service

US Forest Service
P.O. Box 96090
Washington, D.C.
20090-6090

(202) 205-8333

You are here: Home / Search / Publication Information
Bookmark and Share

Publication Information

(115 KB)

Title: Characterization of convective heating in full scale wildland fires

Author: Butler, Bret

Date: 2010

Source: In: Viegas, D. X., ed. Proceedings of the VI International Conference on Forest Fire Research; 15-18 November 2010; Coimbra, Portugal. Coimbra, Portugal: University of Coimbra. 9 p.

Publication Series: Not categorized

Description: Data collected in the International Crown Fire modeling Experiment during 1999 are evaluated to characterize the magnitude and duration of convective energy heating in full scale crown fires. To accomplish this objective data on total and radiant incident heat flux, air temperature, and horizontal and vertical gas velocities were evaluated. Total and radiant energy fluxes were measured. Temperatures were measured using bare Type K 0.13 mm wire diameter thermocouples. Gas velocities were measured using pitot-static type sensors designed specifically for velocity measurements in fires. The experiments occurred in 14 m tall jack pine stands. Flames were 18-25 m tall, fire spread rates were between 0.5 and 1.0 m-s-1. The magnitudes of the temperatures presented are representative of those found in naturally occurring wildland fires. The measured peak gas temperatures varied from 1000 to 2000 K, and gas velocities of 10 to 20 m-s-1. Convective heating rates reached 150 kW-m-2 for short durations (5 to 10 seconds) with sustained flux rates of 40 to 80 kW-m-2 for durations of (~20 to 40 s). The data suggest that maximum convective heat transfer coefficients to the sensor face range from 30 to 50 W-m-2-K-1.

Keywords: fire Behavior, fire Intensity

Publication Notes:

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

XML: View XML

Citation:


Butler, B. W. 2010. Characterization of convective heating in full scale wildland fires. In: Viegas, D. X., ed. Proceedings of the VI International Conference on Forest Fire Research; 15-18 November 2010; Coimbra, Portugal. Coimbra, Portugal: University of Coimbra. 9 p.

 


 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.