Skip to page content
USDA Forest Service
  
Treesearch

Research & Development Treesearch

 
Treesearch Home
About Treesearch
Contact Us
Research & Development
Forest Products Lab
International Institute of Tropical Forestry
Northern
Pacific Northwest
Pacific Southwest
Rocky Mountain
Southern Research Station
Help
 

Science.gov - We Participate


USA.gov  Government Made Easy


Global Forest Information Service

US Forest Service
P.O. Box 96090
Washington, D.C.
20090-6090

(202) 205-8333

You are here: Home / Search / Publication Information
Bookmark and Share

Publication Information

View PDF (2.5 MB)

Title: Accounting for structural compliance in nanoindentation measurements of bioceramic bone scaffolds

Author: Vivanco, Juan; Jakes, Joseph E.; Slane, Josh; Ploeg, Heidi-Lynn;

Date: 2014

Source: Ceramics International, 40,+ 2014; pp. 12485-12492.

Publication Series: Scientific Journal (JRNL)

Description: Structural properties have been shown to be critical in the osteoconductive capacity and strength of bioactive ceramic bone scaffolds. Given the cellular foam-like structure of bone scaffolds, nanoindentation has been used as a technique to assess the mechanical properties of individual components of the scaffolds. Nevertheless, nanoindents placed on scaffolds may violate the rigid support assumption of the standard Oliver–Pharr method currently used in evaluating the Meyer hardness, H, and elastic modulus, Es, of such structures. Thus, the objective of this research was to use the structural compliance method to assess whether or not specimen-scale flexing may occur during nanoindentation of bioceramic bone scaffolds and to remove the associated artifact on the H and Es if it did occur. Scaffolds were fabricated using tricalcium phosphate and sintered at 950°C and 1150°C, and nanoindents were placed in three different (center, edge, and corner) scaffold locations. Using only the standard Oliver–Pharr analysis it was found that H and Es were significantly affected by both sintering temperature and nanoindents location (p00.05). However, specimen-scale flexing occurred during nanoindentation in the 1150°C corner location. After removing the effects of the flexing from the measurement using the structural compliance method, it was concluded that H and Es were affected only by the sintering temperature (p00.05) irrespective of the nanoindent locations. These results show that specimen-scale flexing may occur during nanoindentation of components in porous bioceramic scaffolds or in similar structure biomaterials, and that the structural compliance method must be utilized to accurately assess H and Es of these components.

Keywords: Bioceramic, Bone scaffold, Nanoindentation, Musculoskeletal injuries

Publication Notes:

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

XML: View XML

Citation:


Vivanco, Juan; Jakes, Joseph E.; Slane, Josh; Ploeg, Heidi-Lynn 2014. Accounting for structural compliance in nanoindentation measurements of bioceramic bone scaffolds. Ceramics International, 40+, 2014; pp. 12485-12492.

 


 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.