Skip to page content
USDA Forest Service
  
Treesearch

Research & Development Treesearch

 
Treesearch Home
About Treesearch
Contact Us
Research & Development
Forest Products Lab
International Institute of Tropical Forestry
Northern
Pacific Northwest
Pacific Southwest
Rocky Mountain
Southern Research Station
Help
 

Science.gov - We Participate


USA.gov  Government Made Easy


Global Forest Information Service

US Forest Service
P.O. Box 96090
Washington, D.C.
20090-6090

(202) 205-8333

You are here: Home / Search / Publication Information
Bookmark and Share

Publication Information

View PDF (3.0 MB bytes)

Title: Air Quality at Devils Postpile National Monument, Sierra Nevada Mountains, California, USA

Author: Burley, Joel D.; Bytnerowicz, Andrzej; Buhler, Monica; Zielinska, Barbara; Schweizer, Donald; Cisneros, Ricardo; Schilling, Susan; Varela, Jennifer Chapman; McDaniel, Mark; Horn, Michelle; Dulen, Deanna;

Date: 2016

Source: Aerosol and Air Quality Research

Publication Series: Scientific Journal (JRNL)

Description: Ambient concentrations of O3, PM2.5, NH3, NO, NO2, HNO3, SO2 and VOCs were measured at Devils Postpile National Monument (DEPO) during the summer seasons of 2013 and 2014. The measurements were impacted by the Aspen and Rim Fires in 2013, and the French and King Fires in 2014. While O3 concentrations were not discernibly perturbed by the fire events, the 70 ppb threshold (8-hour average) corresponding to both the current California Ambient Air Quality Standard (CAAQS) and the new National Ambient Air Quality Standard (NAAQS) was exceeded on five days during 2013, and on 16 days during 2014. The older NAAQS of 75 ppb (8-hour average) was exceeded once in 2013, and six times in 2014. Exceedances of the CAAQS or NAAQS occurred when background sources of O3 were augmented by regional-scale transport, at higher altitudes, of polluted air masses that had passed through the San Joaquin Valley before arriving at the DEPO site. The 2013 Aspen Fire elevated PM2.5 to a maximum hourly concentration of 214 µg m–3 and a maximum 24 h mean of 92.7 µg m–3, and resulted in 13 exceedances of the 35 µg m–3 (24 h average) NAAQS for PM2.5. The 2013 Rim Fire increased PM2.5 to a maximum hourly concentration of 132 µg m–3 and a maximum 24 h mean of 69.6 µg m–3, and resulted in two exceedances of the 24 h NAAQS. Concentrations of NH3 increased during all fires, as did those of NO2 during the Aspen and Rim Fires. Concentrations of benzene increased substantially during the French Fire.

Supplemental information is also available.

Keywords: Ozone, Passive samplers, PM2.5, VOC, Nitrogen oxides.

Publication Notes:

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

XML: View XML

Citation:


Burley, Joel D.; Bytnerowicz, Andrzej; Buhler, Monica; Zielinska, Barbara; Schweizer, Donald; Cisneros, Ricardo; Schilling, Susan; Varela, Jennifer Chapman; McDaniel, Mark; Horn, Michelle; Dulen, Deanna 2016. Air Quality at Devils Postpile National Monument, Sierra Nevada Mountains, California, USA. Aerosol and Air Quality Research. 16(10): 2315-2332.

 


 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.