Title: Room/corner tests of wall linings with 100/300 kW burner

Author: Dietenberger, M. A.; Grexa, O.; White, R. H.; Sweet, M. S.; Janssens, M.;

Date: 1995

Source: Proceedings, 4th International Fire and Materials Conference, 1995 November 15-16, Crystal City, Washington. London, UK : Inter Science Communications, [1996].:p. 53-62.

Publication Series: Miscellaneous Publication

Description: Six room/comer tests of common wall linings were conducted with gypsum-lined ceiling exposed to propane burning at 100 kW for 10 min followed by 300 kW for 10 min. This test protocol is an option provided by ISO 9705. The flashover event occurred at 1,000 kW rate of heat release within several seconds of observing flames out the doorway. The time to flashover of the fire-retardant-treated polyurethane foam was 10.5 rein, which contrasts with no flashover for some melting materials exposed to propane burning at 40 and 160 kW. The time to flashover for all the wood materials tested ranged widely from 3 to 15 rein, with the longest times for fire retardant-treated plywoods. This result provides effective indications of fire performance for common materials. A correlation between time to flashover with flame spread index from ASTM E84 along with thermophysical properties measured in the cone calorimeter is presented.

Keywords: Fire effects, Fire resistance, Walls. , Building materials, Burning, Testing, Fire testing

Publication Notes:

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

XML: View XML

Citation:


Dietenberger, M. A.; Grexa, O.; White, R. H.; Sweet, M. S.; Janssens, M. 1995. Room/corner tests of wall linings with 100/300 kW burner. Proceedings, 4th International Fire and Materials Conference, 1995 November 15-16, Crystal City, Washington. London, UK : Inter Science Communications, [1996].:p. 53-62.

 


 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility