Skip to page content
USDA Forest Service
  
Treesearch

Research & Development Treesearch

 
Treesearch Home
About Treesearch
Contact Us
Research & Development
Forest Products Lab
International Institute of Tropical Forestry
Northern
Pacific Northwest
Pacific Southwest
Rocky Mountain
Southern Research Station
Help
 

Science.gov - We Participate


USA.gov  Government Made Easy


Global Forest Information Service

US Forest Service
P.O. Box 96090
Washington, D.C.
20090-6090

(202) 205-8333

You are here: Home / Search / Publication Information
Bookmark and Share

Publication Information

View PDF (189 KB bytes)

Title: Simulating wall and corner fire tests on wood products with the OSU room fire model

Author: Tran, H. C.;

Date: 1994

Source: Fire and flammability of furnishings and contents of buildings. Philadelphia, PA : American Society for Testing and Materials, 1994. STP ; 1233.:p. 153-168.

Publication Series: Miscellaneous Publication

Description: This work demonstrates the complexity of modeling wall and corner fires in a compartment. The model chosen for this purpose is the Ohio State University (OSU) room fire model. This model was designed to simulate fire growth on walls in a compartment and therefore lends itself to direct comparison with standard room test results. The model input were bench-scale data obtained from the ASTM Test Method for Heat and Visible Smoke Release Rates for Materials and Products (E 906). Six wood materials were tested in the bench-scale test and also in an ASTM room fire test (proposed method). The simulations from the OSU model were compared with the database of 26 room tests representing a range of conditions. We treated the model as a black box and only varied the input data. The criteria used for comparison were heat release rate. radiative heat flux to the floor. and upper layer temperature. The agreement between model predictions and experiments varied. We conclude that the OSU model in its present state of development is not able to track fire growth in scenarios of the burner source against the back wall. The accuracy of the bench-scale data and methods to reduce the input data play a very important role in the simulation results. This work also raises many important issues such as the need for clear documentation of the modeling process and the definition of criteria for determining good agreement between the model simulation and experimental results.

Keywords: Fire behavior, Wood products, FIre models, Fire testing, Room fire tests

Publication Notes:

  • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
  • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

XML: View XML

Citation:


Tran, H. C. 1994. Simulating wall and corner fire tests on wood products with the OSU room fire model. Fire and flammability of furnishings and contents of buildings. Philadelphia, PA : American Society for Testing and Materials, 1994. STP ; 1233.:p. 153-168.

 


 [ Get Acrobat ]  Get the latest version of the Adobe Acrobat reader or Acrobat Reader for Windows with Search and Accessibility

USDA logo which links to the department's national site. Forest Service logo which links to the agency's national site.